i-FAST also providing various training on Industrial Fire, Safety, Road Safety, Safety aspect on Construction, Height Work, Scaffolding, Confine Space, Crane Operation, conducting Mock Drill on Emergency Preparedness, Disaster Management Onsite/ Offsite emergency, Survey & Audit as a Trained & Competent consultancy through eminent experts.

The institution impart "hands" on training on Fire Extinguishers, Fire Appliances and fixed fire fighting installation and automatic fire alarm systems along with their maintenance technique as per national and international standard. The institution has rich infrastructure for the Schedule courses. This includes hostel facilities for the trainees.

After successful completion of their training courses, Private trainees get employed in the various industries in the field of fire safety / fire fighting fire equipment maintenance wings.

Audit

Fire safety audit is an effective tool for assessing fire safety standards of an organization or occupancy. A comprehensive fire safety audit should address the inherent fire hazardous associated with the day to day activities in an occupancy and recommend measures to reduce the potential fire hazards.

The main objective of safety audit is to carry out a systematic, critical appraisal of all potential hazards involving personnel, plant, services and operation method and to ensure that Safety and Health system fully satisfy the legal requirements as well as employees feel safe to work in the organization.

FAST Consultant Assessment

FAST consultant will assess a broad range of Fire risk factors including:

  • Sources of ignition
  • Means of escape
  • Warning systems
  • Risk to personnel
  • Evaluating emergency plans
  • Fire and Explosion prevention & protection
  • Emergency management in Industries, Corporates, Hospitals, Hotels, High Rise buildings & Commercial Complexes

Third-party Fire Audit

As per Odisha Fire Safety rules

Scope of Work

1. Objective

To conduct an independent, impartial third-party fire safety audit to evaluate the adequacy, effectiveness, and compliance of existing fire prevention, fire protection, and life safety measures in accordance with Odisha Fire Safety Rules, ensuring statutory compliance and risk mitigation.

2. Applicable Codes & Regulations

  • Odisha Fire Safety Rules & Guidelines
  • Odisha Fire Service Act
  • National Building Code (NBC) of India
  • BIS / IS Codes (Relevant to Fire Protection)
  • Factory Act provisions (where applicable)
  • TAC / Insurance Guidelines

3. Scope of Third-Party Fire Audit

3.1 Review of Documents

  • Approved fire safety drawings & layouts
  • Fire Safety Certificate / Fire NOC status
  • Fire emergency & evacuation plan
  • Records of inspection, testing & maintenance
  • Training & mock drill records
  • Occupancy & usage details

3.2 Physical Inspection & Verification

  • Fire detection & alarm system
  • Fire pumps, pump house & water storage tanks
  • Hydrant, hose reel & sprinkler systems
  • Portable & trolley-mounted fire extinguishers
  • Emergency exits, staircases & refuge areas
  • Emergency lighting & exit signage
  • Fire doors, fire separation & compartmentation
  • Electrical panels & cable routing (visual check)
  • Housekeeping & fire load assessment

3.3 Compliance Assessment

  • Verification of compliance with Odisha Fire Safety Rules
  • Gap analysis against NBC & BIS standards
  • Identification of non-conformities
  • Classification of observations as Critical / Major / Minor
  • Risk rating: High / Medium / Low

3.4 Fire Prevention & Life Safety Assessment

  • Means of egress adequacy
  • Occupant load & travel distance
  • Fire load & hazardous material storage
  • Accessibility for fire tenders
  • Fire command & control arrangements

4. Audit Deliverables

  • Third-Party Fire Safety Audit Report
  • Detailed observations with photographs
  • Compliance & non-compliance statement
  • Risk-wise recommendations
  • Corrective & Preventive Action Plan (CAPA)
  • Audit summary for submission to Odisha Fire Service

5. Methodology

  • Site inspection by qualified fire safety professionals
  • Use of standardized audit checklists
  • Reference to statutory rules & codes
  • Independent evaluation without conflict of interest

6. Manpower Deployment

  • Certified Fire Safety Auditor
  • Fire Officer / Safety Engineer
  • Technical support staff (as required)

7. Client Responsibilities

  • Access to all areas of the premises
  • Availability of relevant documents & drawings
  • Nomination of responsible site coordinator

8. Exclusions

  • Design modification & system upgradation works
  • Supply or installation of firefighting equipment
  • Third-party testing fees
  • Statutory application fees

Conclusion

The Third-Party Fire Safety Audit shall provide an objective, compliant, and actionable assessment to support Fire NOC issuance / renewal, enhance fire preparedness, and reduce fire risk as per Odisha Fire Safety Rules.